Recommended
1. Try to connect to a person through the bpcd port. If that fails, make sure bpcd starts the entire client and that point 2 is confirmed when it picks up the phone.
Why do I get a message when I reboot Veritas?
If each swap volume listed in / etc / vfstab succeeds when upgrading_startis is executed, the current upgrade_finish script will initiate resynchronization of the number. This can result in a message similar to the following when issuing a command to reboot the system: xvm: vxvol: tutil0 field for plex plex_name terminated unexpectedly
2. If the destination is behind a firewall, try opening the bpcd (13782) and vnetd (13724) ports. Also check if they can be entered correctly in the company file.
3. In the NetBackup Administration Console, open NetBackup Management> Host Properties> Master Server> Double-click Known Server> Client Attributes, check the port and connection settings.
4. If you run bpclntcmd -pn from someone, make sure it returns the short name or fully qualified domain name of the executing server. In any case, make sure that it can be described as in the client’s server list via the BAR-GUI.
DO THIS TWICE if you get the same answer more than once?
Are you giving the same answer TWICE?
DO IT TWICE, do you get the lady’s answer both times?
Is this on another cool network? how is the web service master?
if they work because of host files. Then you needlook up DNS or the mainstream media to see what is logged each day. that.
You may be missing one or more rules, or you have one or more incorrectly configured rules.
Review the inbound firewall rules for each rule configured by the client for NetBackup.
If you include the letters “nbu” in all NetBackup names, you can list the rule names yourself with:
> netsh advfirewall Firewall show Strategy name = ALL | find / I "nbu"
… and a detailed list of all the rules you’ve created specifically for NetBackup:
> Netsh advfirewall showing rule name = my rule's verbose name
Please do not include any rules or warnings on Windows — only enable the rules you created for NetBackup.
My Netbackup is version 7.1 installed on every Windows Server 2008 R2 computer and supports approximately 20 clients running specialty operating systems from Windows XP to Server 2008 and Redhat computers.
I have a BMR backup on Windows Server R2 2008 which was created in July 2016 and has been restored several times without any problem. The last restoration could have been done in September 2016.
But during this 7 day period, when I try, I get an error in the specific BMR client (see the merged file).
And now I don’t know what to do to make a person’s recovery turn green.
Recommended
Is your PC running slow? Do you have problems starting up Windows? Don't despair! Fortect is the solution for you. This powerful and easy-to-use tool will diagnose and repair your PC, increasing system performance, optimizing memory, and improving security in the process. So don't wait - download Fortect today!
Item: 100017409
Last Published: 23.03.2018
Notes: 3
Problem
STATUSCODE 37: Known Reasons for Receiving NetBackup Status Code 37 Invalid Operation Requested By Server
Error Message
Solutions
More often than not, status code 37 can be the result of the portable media server name not appearing in the list of servers associated with the core server.
– For UNIX Excel on servers add the line SERVER according tothere is
, which Bp.conf folder on the main server. Add an entry after any existing ones. SERVER =
systems in bp.conf file. A
How does Veritas report errors to the OS?
Veritas depends on operating system drivers to communicate with hard drives. When I / O errors occur, device drivers report them to Veritas. Vxdmp recognizes passed errors to ensure that you are being affected by device drivers and can disable the path in response to our events.
special person. Stop any NetBackup daemons / services running the master server.
Secondly. Although NetBackup has stopped all daemons / services on some master servers, rename it. bprd.d directory bprd.d_old
3. Create each new void. the bprd.d directory on the main server theme
– For Windows servers, add new media devices to the master server’s mailing list by opening the NetBackup Administration Console and in the Host Properties section select Master Server. In the right pane, double-click Discover Master Server and go to the Servers section. Add these new server names to the host list.
After To add a server to the server list on the UNIX Helper server, stop and start the NetBackup Request Daemon (bprd) and the NetBackup Client Base Manager Daemon (bpdbm) for the lifestyle changes to take effect. When checking the server, shut down Windows and also restart NetBackup Request Manager, services NetBackup Database Manager for which the changes will take effect. A
Problem This could be observed with name resolution problems. Confirm that the information about the server generating the added status code 37 often includes the names of the Domain Name System (DNS) agents and / or the local host file about how the environment resolves domain names. A
In previous incidents, status code 37 must have been caused by corruption of lock files at the intervals that the master server was using. bprd.d free info / usr / openv / netbackup / bin ( become a UNIX server expert, and
Master Server The bpcd report can repeatedly render a presentation like the following:
<16> valid_server bpcd:
To move corrupted lock files, generally follow these steps:
Speed up your PC today with this easy-to-use download.Ongeldig Foutnummer Veritas
Numero Di Errore Non Valido Veritas
Numero De Error No Valido Veritas
Numero De Erro Invalido Veritas
Numero D Erreur Invalide Veritas
Ungultige Fehlernummer Veritas
Nieprawidlowy Numer Bledu Veritas
잘못된 오류 번호 베리타스
Nevernyj Nomer Oshibki Veritas
Ogiltigt Felnummer Veritas